The INTERCALL 700 is the latest innovation in
the Intercall range of advanced call system. The system boasts all the
features of the Intercall 600 system together with hands free two way
speech facilities between all audio units.
It features 7 levels of call, hands free
two way intercom, integral infra red receiver, audio page facility,
re-assurance LED & ‘call waiting’ sounder. The industry
standard jack socket will accept a host of triggering devices. The unit
may be flush or surface mounted using the Intercall BB1 Backbox.
All room call points have an integral infra
red receiver, which allows a call to be generated away from the call
point without the need for trailing wires. Using the TIR4 Infra Red
Trigger it is possible to identify the calling resident together with
their location, which can be used to rout the call to specific members
of staff.
The system is fully addressable and only requires connection to a
common 12v network cable. The system is configured using a PC
compatible Computer or similar and may be programmed on or off site as
required.
L752 AUDIO
CALL POINT
An L752 Audio Call Point is required for every individual audio call
location on the system.
L722
NON AUDIO CALL POINT
The L722 Non Audio Call Point contains identical features to the audio
call point described above but without the intercom facility. Options
which must be specified when ordering include: emergency call only
& non-latching operation for telephone ring detectors etc.
L758 AUDIO DISPLAY UNIT
Audio
display units are generally located throughout the establishment and
provide a description of the call type, location and identity of caller
together with sounding the integral alarm. It features 2 line back-lit
display, multi function audible alarm, two way intercom facility and
audio page facility to all other displays and to all members of staff
present within a residents bedroom
L762 CALL/DISPLAY UNIT
The L762 Call Display Unit combines the features of the speech call
point with a built in display. When in staff present mode the unit will
display all calls on the system in full alphanumeric text, enabling
staff to speak to other callers elsewhere on the system without having
to leave the room they are attending.
L722DK
DOOR MONITORING POINT
The L722DK Door Monitoring Point can be used to protect fire doors,
exit doors and other sensitive areas. The unit has an isolated
key-switch in place of the jack socket, which can be used by authorized
personnel to isolate the unit and prevent it from activating the alarm.
The L722DK activates an “Emergency” call as standard and
can be reset with a single press of the reset button.
L714 REMOTE SOUNDER WITH
RELAY
Remote sounders are used in areas where an audible alarm is required to
attract attention but no indication of call location is required. The
sounder is similar in operation to a display unit with a multi level
alarm, but has limited zoning facilities. Any assistance or emergency
call on the system will over-ride the standard call tone. The unit is
fitted with a relay that provides normally open and normally closed
‘dry’ contacts, which can be used to trigger auxiliary
devices.
L746 OVERDOOR LIGHT
Overdoor
lights are an optional item normally positioned above the door in a
corridor to indicate the status of the call point(s) within the room.
The L746 can also be used to monitor several call point addresses for
end of corridor indication, or as a “follow me” light. Each
unit is fitted with twin ultra-bright LED’s which mimic the
reassurance indicator on the call points. The L746S unit operates in
the same way as the standard overdoor light but has the addition of an
integral sounder.
L717 & L737 POWER SUPPLY
The
L717 Power Supply provides the main power to the system. It requires a
mains supply connection and it houses the backup battery, required to
safeguard the system in the event of a mains failure. The power supply
stores all the text programming information and can also be used to
configure the system when a laptop is connected. The L737 Booster Power
Supply unit is designed to increase the permitted number of units and
quantity of cable allowed on any one system. It works by re-producing
the signals made by the power supply, and several booster units may be
connected as required.
PRINTERS AND
ALPHANUMERIC PAGERS
Printers and alphanumeric pagers can be connected to the system with
the L747 Universal Interface. The printer provides a permanent printed
record of all system activity together with date and time. Pagers can
be configured to display calls made on the system as they would appear
on the display unit. This allows staff to carry on with their work
without having to worry about missing calls. Pagers can also be
specially configured to only receive certain calls, or calls at certain
times of the day.
CMS LITE CALL
MANAGEMENT SOFTWARE
The CMS Lite Call Management Software allows you to record and store
all Intercall system activity on your personal computer. Giving you
immediate access to information, it is easy to access the call history
of a resident, keeping you in charge of your home. Staff pagers can
also be controlled from your computer, allowing free text messages to
be sent to individual pagers.
TIR4
INFRA RED TRIGGER
The TIR4 Infra Red Trigger allows calls to be made from any location
covered by the system. It operates by triggering the local IR call
point when the button is pressed, allowing the exact location of the
resident to be displayed. The TIR4 triggers requires the use of L722
Call Points which have built in Infra Red receivers, to trigger the
system.
Download PDF installation & operation guide
|